The DODO AQUA PRESSURE (DOT-PRS-200) is an industrial stainless-steel line pressure transmitter measuring 0–6 bar gauge pressure with ±0.3 % F.S. accuracy (±0.018 bar). It screws into a standard G1/2 male port and features an SS304 shell with a welded SS316L isolation diaphragm, handling water, oil, hydraulic fluid and compressed air without a separate seal. With 200 % overload capacity (up to 12 bar), it withstands pump surges and water hammer. It outputs over RS-485 Modbus-RTU, runs on DC 12–36 V with reverse-polarity protection, and ships with a 2 m cable and GX12 connector fitted.
حساس DODO AQUA PRESSURE (DOT-PRS-200) هو محوّل ضغط خطوط صناعي من الستانلس ستيل يقيس الضغط النسبي من 0 إلى 6 بار بدقة ±0.3% من كامل المدى (±0.018 بار). يُركَّب مباشرة على منفذ G1/2 ذكر قياسي، ويتميز بجسم SS304 وغشاء عزل ملحوم SS316L، مما يتيح قياس الماء والزيت والسوائل الهيدروليكية والهواء المضغوط دون الحاجة لعازل إضافي. بفضل قدرة تحمّل زائد 200% (حتى 12 بار) يتحمل صدمات المضخات والمطرقة المائية. يعمل بواجهة RS-485 Modbus-RTU وبجهد 12–36 فولت DC مع حماية من عكس القطبية، ويأتي مع كابل 2 متر وموصل GX12 مركّب.
موصل GX12 للتوصيل المباشر مع DODO LOGGER لعرض القراءات وتخزينها ومراقبتها من خلال منصة DODOTIK PLATFORM وتطبيق DODOLINK.
The DODO AQUA PRESSURE is part of the DODO AQUA family of industrial online water sensors from DODOTiK. It is a stainless-steel line pressure transmitter that screws into a G1/2 port and reports gauge pressure from 0 to 6 bar, the ideal range for water distribution and irrigation systems.
It is the natural companion to the DODO AQUA LEVEL sensor: while the level sensor tells you how much water is in the tank, this transmitter tells you what the line is doing, whether the pump is developing head, whether a filter is blinding, whether the main has lost pressure overnight, or whether an irrigation block is getting the pressure its emitters need.
Process pressure acts on a welded SS316L isolation diaphragm, which transmits it through a fill fluid to a diffused-silicon pressure chip. Since only stainless steel touches the medium, the same transmitter reads water, oil, hydraulic fluid and compressed air. Laser-trimmed temperature compensation holds drift to ±0.02 % F.S. per °C across the −10 to +70 °C compensated range, with ±0.1 % F.S. per year long-term stability.
With 200 % overload capacity, the 6 bar unit survives pressures up to 12 bar without damage, which is critical on pump lines where a quickly closing valve can spike pressure far above normal working levels. The reading is gauge pressure, referenced to atmosphere, so weather changes do not affect it.
The reported unit is bar by default, with MPa, kPa, Pa, mbar, kg/cm², psi and water-column units selectable over the bus. As a standard Modbus-RTU device (default address 1, baud 1200 to 115200 selectable), it connects to any PLC, DCS, SCADA or RS-485 master. With the DODO LOGGER, it plugs in directly via the fitted GX12 4-pin connector, logs to microSD, and publishes to the DODOTiK Platform and DODOLINK mobile app with no programming.
Installation note: always tighten on the hex above the thread, never on the housing, and seal with PTFE tape on the G1/2 thread only.
Specifications
| Parameter | Value |
|---|---|
| Model | DOT-PRS-200 |
| Order code | DA-PRS-R6 |
| Measured parameter | Gauge pressure |
| Measuring principle | Diffused-silicon chip behind SS316L isolation diaphragm |
| Measuring range | 0–6 bar |
| Accuracy | ±0.3 % F.S. (±0.018 bar) |
| Overload capacity | 200 % of range (12 bar) |
| Long-term stability | ±0.1 % F.S. per year |
| Temperature drift | ±0.02 % F.S. per °C |
| Compensated range | −10 to +70 °C |
| Response frequency | < 100 Hz (1200 / 2400 Hz to order) |
| Reported unit | bar default; MPa, kPa, Pa, mbar, kg/cm², psi, water column selectable |
| Calibration | User-settable zero offset; span factory-set |
| Supply voltage | DC 12–36 V (24 V typical) |
| Protection | Reverse polarity and current limiting |
| Output | RS-485, Modbus-RTU |
| Baud rate | 9600 default, selectable 1200–115200 |
| Frame format | 8N1 |
| Default slave address | 1 (changeable, 1–255) |
| Process connection | G1/2 male thread |
| Shell material | SS304 stainless steel |
| Isolation diaphragm | SS316L stainless steel, welded |
| Measuring medium | Water, oil, hydraulic fluid, compressed air |
| Medium temperature | −10 to +70 °C |
| Ambient temperature | −20 to +85 °C |
| Ambient humidity | 0–95 % RH, non-condensing |
| Electrical head | DIN 43650 housing with cable gland |
| Ingress protection | IP65 |
| Cable | 2 m standard |
| Connector | GX12 4-pin female (VCC, GND, A, B) |
| In the box | Transmitter with 2 m cable, test certificate |
| Warranty | 1 year |
Applications