The QNDB7 AC Current Sensor Transmitter measures AC currents up to 10A (12A measuring range) using electromagnetic induction (mutual inductance), with galvanic isolation between the primary and secondary circuits. It runs on a +24V supply and provides a 4-20mA output and an RS485 output. It offers ≤0.5% accuracy, ≤1% FS linearity, a 40-6000Hz bandwidth and 2.5kV isolation. The sensor is small, easy to mount, adds no insertion losses, and is highly resistant to external interference. It suits variable speed drives, welding machines, UPS systems, battery-supplied applications and electrochemical equipment.
حساس وناقل التيار المتردد QNDB7 يقيس التيار المتردد حتى 10A (مدى قياس يصل إلى 12A). يعمل بمبدأ الحث الكهرومغناطيسي (الحث المتبادل) مع عزل جلفاني بين الدائرة الابتدائية والدائرة الثانوية. يعمل على جهد تغذية +24V ويوفر مخرج 4-20mA ومخرج RS485. يتميز بدقة ≤0.5% وخطية ≤1% FS ونطاق ترددي 40-6000Hz وعزل 2.5kV. حجمه صغير وتركيبه سهل، لا يسبب فقدًا في الدائرة المقاسة، ومقاوم بدرجة عالية للتداخل الخارجي. مناسب لمحركات السرعة المتغيرة وماكينات اللحام وأنظمة UPS والتطبيقات التي تعمل بالبطاريات والأنظمة الكهروكيميائية.
The QNDB7 Series AC Current Sensor / Current Transmitter gives accurate electronic measurement of AC currents. It works on electromagnetic induction (mutual inductance), and galvanic isolation separates the primary circuit from the secondary circuit, so the measured line stays electrically isolated from your control or monitoring system.
This model has a rated current of 10A and a measuring range up to 12A. It runs from a +24V (±5%) supply and provides a 4-20mA output and an RS485 output. It has ≤0.5% accuracy, ≤1% FS linearity, a response time under 200ms and a wide 40-6000Hz bandwidth. Galvanic isolation is rated at 2.5kV (50Hz, 1 min).
The current to be measured passes through the sensor, so it adds no insertion losses to the circuit. The design is small and space-saving, easy to mount, and highly immune to external interference. It operates from -20°C to +80°C and weighs about 85g. It complies with SJ 20790-2000 and JB/T 7490-2007.
Directions for use:
Specifications
| Parameter | Value |
|---|---|
| Model | QNDB7 |
| Measured Current Type | AC |
| Rated Current (Ipn) | 10A |
| Measuring Range (Ip) | 12A |
| Output | 4-20mA / RS485 |
| Supply Voltage | +24V (±5%) |
| Load Resistance | ≥ 250Ω |
| Accuracy | ≤ 0.5% |
| Linearity | ≤ 1% FS |
| Quiescent Current Consumption | < 30mA |
| Offset Current | ±0.1mA |
| Offset Current Drift | ≤ 0.005mA/°C |
| Response Time | < 200ms |
| Bandwidth | 40 – 6000Hz |
| Galvanic Isolation | 2.5kV (50Hz, 1 min) |
| Operating Temperature | -20°C to +80°C |
| Storage Temperature | -40°C to +85°C |
| Weight (approx.) | 85g |
| Measuring Principle | Electromagnetic induction (mutual inductance) |
| Standards | SJ 20790-2000; JB/T 7490-2007 |
| Pinout | 1: +24V, 2: GND, 3: Iout, 4: GND |
Applications