The QNDB7 AC Current Sensor Transmitter measures AC currents accurately using electromagnetic induction (mutual inductance), with galvanic isolation between the primary and secondary circuits. This model is rated for 50A AC with a measuring range up to 60A, and gives a DC 4-20mA output and an RS485 output. It runs on a +24V supply and has accuracy of ≤0.5%, a response time under 200ms, and a 40-6000Hz bandwidth. Its small size, easy mounting, and high immunity to external interference suit variable speed drives, welding machines, UPS systems, and battery-supplied applications.
حساس وناقل التيار المتردد QNDB7 يقيس التيارات المترددة بدقة اعتماداً على مبدأ الحث الكهرومغناطيسي (الحث المتبادل)، مع عزل كهربائي (Galvanic Isolation) بين الدائرة الابتدائية والدائرة الثانوية. هذا الموديل مصمم لتيار مقنن 50A AC بمدى قياس يصل إلى 60A، ويعطي خرج DC 4-20mA وخرج RS485. يعمل على جهد تغذية +24V وبدقة ≤0.5% وزمن استجابة أقل من 200ms وعرض نطاق 40-6000Hz. حجمه الصغير وسهولة تركيبه ومناعته العالية ضد التداخل الخارجي تجعله مناسباً لمحركات السرعة المتغيرة وماكينات اللحام وأنظمة UPS والتطبيقات التي تعمل على البطاريات.
The QNDB7 Series AC Current Sensor / Current Transmitter measures AC currents by electromagnetic induction (mutual inductance). Because the primary circuit is galvanically isolated from the secondary circuit, the measured line stays electrically separate from the output side.
This version is rated at 50A AC (Ipn) with a measuring range up to 60A (Ip). It outputs DC 4-20mA and RS485, runs on a +24V (±5%) supply, and needs a load resistance of at least 250Ω. Accuracy is ≤0.5% and linearity is ≤1% FS. Response time is under 200ms and bandwidth is 40-6000Hz. Offset current drift is low, at ≤0.005mA/°C, and isolation is rated at 2.5kV (50Hz, 1 min).
To use the sensor, pass the conductor carrying the current through it and read the signal at the output terminals. Incorrect wiring may damage the sensor. The output amplitude can be adjusted to your requirements, and the sensor can be custom-designed for other rated input currents and output voltages. It operates from -20°C to +80°C and weighs about 85g.
Specifications
| Parameter | Value |
|---|---|
| Model | QNDB7 |
| Measuring Principle | Electromagnetic induction (mutual inductance) |
| Rated Current (Ipn) | 50A AC |
| Measuring Range (Ip) | 60A |
| Output | DC 4-20mA / RS485 |
| Supply Voltage | +24V (±5%) |
| Load Resistance | ≥ 250Ω |
| Accuracy | ≤ 0.5% |
| Linearity | ≤ 1% FS |
| Quiescent Current Consumption | < 30mA |
| Offset Current | ±0.1mA |
| Response Time | < 200ms |
| Offset Current Drift | ≤ 0.005mA/°C |
| Bandwidth | 40 – 6000Hz |
| Galvanic Isolation | 2.5kV (50Hz, 1 min) |
| Operating Temperature | -20°C to +80°C |
| Storage Temperature | -40°C to +85°C |
| Weight (approx.) | 85g |
| Pinout | 1: +24V, 2: GND, 3: Iout, 4: GND |
| Standards | SJ 20790-2000, JB/T 7490-2007 |
Applications