The QNDB7 AC Current Sensor Transmitter provides accurate electronic measurement of AC currents using the principle of electromagnetic induction (mutual inductance), with galvanic isolation between the primary and secondary circuits. This model is rated for 500A AC with a measuring range up to 600A, and delivers a 4-20mA output with RS485 communication, powered from a +24V supply. It offers ≤0.5% accuracy, ≤1% FS linearity, a response time under 200ms, and 2.5kV isolation. Its small size, easy mounting, and high immunity to external interference make it suitable for drives, welding machines, UPS systems, and electrochemical applications.
يوفر حساس وناقل التيار المتردد QNDB7 قياساً إلكترونياً دقيقاً للتيارات المترددة بالاعتماد على مبدأ الحث الكهرومغناطيسي (الحث المتبادل)، مع عزل كهربائي (Galvanic Isolation) بين الدائرة الأولية والدائرة الثانوية. هذا الموديل مصمم لتيار مقنن 500A AC بمدى قياس يصل إلى 600A، ويعطي خرجاً بقيمة 4-20mA مع اتصال RS485، ويعمل بجهد تغذية +24V. يتميز بدقة ≤0.5% وخطية ≤1% FS وزمن استجابة أقل من 200ms وعزل يصل إلى 2.5kV. كما يتميز بصغر الحجم وسهولة التركيب ومناعة عالية ضد التداخلات الخارجية، مما يجعله مناسباً لمحركات السرعة المتغيرة وماكينات اللحام وأنظمة UPS والتطبيقات الكهروكيميائية.
The QNDB7 Series AC Current Sensor / Current Transmitter is designed for accurate electronic measurement of AC currents. It operates on the measuring principle of electromagnetic induction (mutual inductance) and provides galvanic isolation between the primary and secondary circuits, keeping the measured high-current circuit electrically separated from the output and control side.
This model is rated at 500A AC (Ipn) with a measurement range of up to 600A (Ip). It converts the measured current into a 4-20mA output signal and also provides an RS485 output, and it operates from a +24V (±5%) supply. With ≤0.5% accuracy, ≤1% FS linearity, an offset current of ±0.1mA, and a low offset current drift of ≤0.005mA/°C, it delivers stable and reliable readings. It responds in less than 200ms, covers a bandwidth of 40 to 6000Hz, and draws less than 30mA quiescent current.
The sensor offers 2.5kV galvanic isolation (50Hz, 1 min), operates from -20°C to +80°C, and weighs about 85g. It is manufactured to the SJ 20790-2000 and JB/T 7490-2007 standards.
Using it is simple: the current to be measured passes through the sensor, and the output is read at the output terminals. Correct wiring is essential, as wrong wiring may damage the sensor. The output amplitude can be adjusted according to user requirements, and custom designs with different rated input currents and output voltages are available.
Pin Connections:
Specifications (Ta = 25°C ±5°C)
| Parameter | Value |
|---|---|
| Model | QNDB7 |
| Measuring Principle | Electromagnetic induction (mutual inductance) |
| Rated Current (Ipn) | 500A AC |
| Measure Range (Ip) | 600A |
| Output | 4-20mA, RS485 |
| Supply Voltage | +24V (±5%) |
| Load Resistance | ≥ 250Ω |
| Accuracy | ≤ 0.5% |
| Linearity | ≤ 1% FS |
| Quiescent Current Consumption | < 30mA |
| Offset Current | ±0.1mA |
| Offset Current Drift | ≤ 0.005mA/°C |
| Response Time | < 200ms |
| Bandwidth | 40 – 6000Hz |
| Galvanic Isolation | 2.5kV (50Hz, 1 min) |
| Operating Temperature | -20°C to +80°C |
| Storage Temperature | -40°C to +85°C |
| Mass (approx.) | 85g |
| Standards | SJ 20790-2000; JB/T 7490-2007 |
| Pinout | 1: +24V, 2: GND, 3: Iout, 4: GND |
Applications