500AThe QNDB7 AC Current Sensor Transmitter measures AC current electronically using electromagnetic induction (mutual inductance). It provides galvanic isolation between the primary and secondary circuits, which keeps the measured line electrically separate from the output side. It runs from a +24V supply and gives two outputs: 4-20mA and RS485. It offers ≤0.5% accuracy, a response time under 200 ms, and a 40–6000 Hz bandwidth. The conductor passes straight through the sensor, so it adds no insertion loss. It is small, easy to mount and highly resistant to interference. It comes in 5A, 10A, 20A, 50A, 100A and 500A versions.
مُرسِل حساس التيار المتردد QNDB7 يقيس التيار المتردد (AC) إلكترونياً باستخدام مبدأ الحث الكهرومغناطيسي (الحث المتبادل). يوفر عزلاً كهربائياً (Galvanic Isolation) بين الدائرة الابتدائية والدائرة الثانوية، فيبقى الخط المُقاس منفصلاً كهربائياً عن جهة المخرج. يعمل على مصدر تغذية +24V ويعطي مخرجين: 4-20mA وRS485. يتميز بدقة ≤0.5% وزمن استجابة أقل من 200 ms وعرض نطاق 40–6000 Hz. يمر الموصل مباشرة عبر الحساس، لذلك لا يسبب أي فقد إدخال. وهو صغير الحجم وسهل التركيب وعالي المقاومة للتداخل. يتوفر بإصدارات 5A و10A و20A و50A و100A و500A.
The QNDB7 AC Current Sensor Transmitter is an electronic sensor for measuring AC current. It works on the principle of electromagnetic induction (mutual inductance). Its galvanic isolation of 2.5 kV between the primary and secondary circuits keeps the measured line electrically separate from the control or monitoring equipment.
To use it, pass the current-carrying conductor through the sensor and read the signal from the output terminals. Because the conductor goes straight through, the sensor adds no insertion loss to the measured circuit. Incorrect wiring may damage the sensor, so follow the pinout carefully.
The transmitter runs from a +24V (±5%) supply and gives a 4-20mA analog output together with RS485 communication. It has an accuracy of ≤0.5%, linearity of ≤1% FS, a response time under 200 ms, a 40–6000 Hz bandwidth and low offset drift of ≤0.005 mA/°C. It works from -20°C to +80°C.
The output amplitude can be adjusted to suit the user’s needs, and custom versions are available for other rated input currents and outputs.
Available versions:
| Rated Current (Ipn) | Measuring Range (Ip) |
|---|---|
| 5A AC | 6A |
| 10A AC | 12A |
| 20A AC | 24A |
| 50A AC | 60A |
| 100A AC | 120A |
| 500A AC | 600A |
| Parameter | Value |
|---|---|
| Model | QNDB7 |
| Measured Current Type | AC |
| Measuring Principle | Electromagnetic induction (mutual inductance) |
| Rated Current (Ipn) | 5A / 10A / 20A / 50A / 100A / 500A |
| Measuring Range (Ip) | 6A / 12A / 24A / 60A / 120A / 600A |
| Output | 4-20mA / RS485 |
| Supply Voltage | +24V (±5%) |
| Load Resistance | ≥ 250 Ω |
| Accuracy | ≤ 0.5% |
| Linearity | ≤ 1% FS |
| Quiescent Current | < 30 mA |
| Offset Current | ±0.1 mA |
| Offset Current Drift | ≤ 0.005 mA/°C |
| Response Time | < 200 ms |
| Bandwidth | 40 – 6000 Hz |
| Galvanic Isolation | 2.5 kV (50 Hz, 1 min) |
| Operating Temperature | -20°C to +80°C |
| Storage Temperature | -40°C to +85°C |
| Weight (approx.) | 85 g |
| Test Conditions | Ta = 25°C ±5°C |
| Standards | SJ 20790-2000, JB/T 7490-2007 |
| Pinout | Pin 1: +24V, Pin 2: GND, Pin 3: Iout, Pin 4: GND |